-
Load flow study
28 Lessons-
StartDay 1: Introduction of Digsilent
-
StartDay 2: Transformer paralleling, transformer losses, Transformer OLTC Selection .
-
StartHand- on 1
-
StartHand on - 2
-
StartDay 3: Session 1: Transmission line modelling
-
StartDay 3: Session 2: Ferranti effect
-
StartDay 3: Breakout Room 1
-
StartDay 4: Session 1: Surge Impedance Loading, Cable Modelling,
-
StartDay 4: Session 2: ZIP Load Modelling and MV Load Modelling
-
StartDay 4: Breakout Room 1
-
StartDay 4: Breakout Room 2
-
StartDay 5 :Reactive power Compensation, Power Factor Correction, Fixed and Variable Capacitor bank Modelling
-
StartDay 5: Breakout Room 1
-
StartDay 5: Breakout Room 2
-
StartDay 5: Excel sheet
-
StartDay 6:Capability curve modelling, Inverter operation with respect to real and reactive power and performing load flow analysis
-
StartDay 7: session 1:Solar Plant design and reactive power control using station controller and hands on session
-
StartDay 7: session 2:Solar Plant design and reactive power control using station controller and hands on session
-
StartDay 7: Hands on session
-
StartDay 8: Power plant controller - power frequency controller option and load flow analysis options
-
StartDay 8: Breakout Room
-
StartDay 9: Synchronous Generator Modelling, Modes of Operation And Synchronous condenser Modelling
-
StartDay 9: Synchronous Condenser Modelling and Breakout Room
-
StartDay 9: Excel sheet
-
StartDay 10: OLTC Modelling for Three winding transformer , DC Microgrid modelling(PV,DC-DC Converter)
-
StartDay 10: Wind turbine modelling, DC Microgrid Handson
-
StartDay 11: Steel plant Handson Session-1
-
StartDay 11: Steel plant Handson Session-2
-
-
Short circuit study
30 Lessons-
StartIntroduction about short circuit analysis, IEC-60909 Assumption factor
-
StartGrid Short Circuit Calculation
-
StartExcel Calculation
-
StartFault Far from Source and Fault Near to Source
-
StartOverview of SC Standards & DC component
-
StartHands On
-
StartExcel Calculation
-
StartTransformer Short Circuit current calculation, Sequence diagram
-
StartAssignment Question-1
-
StartSequence Component and Different winding fault observation
-
StartSignificance of X/R ratio
-
StartSequence Component PPT
-
StartSignificance of X/R
-
StartTypes of Grounding and its classification using Digsilent
-
StartBasics of Grounding and its types
-
StartShort Circuit Analysis PPT
-
StartKR_Monograph
-
StartBreaking, Making, DC current, Minimum and Maximum Fault
-
StartHands On
-
StartExcel
-
StartShort Circuit Study for Grid connected and Off Grid system
-
StartHands On
-
StartSC steel Plant SLD
-
StartSteel Plant Parameter
-
StartMethods to limit the fault current
-
StartAssignment Question Review
-
StartFault Current Limitation
-
StartOverview of short circuit study Input for each equipment
-
StartExplanation about Steel Plant SLD assignment
-
StartSteel Plant SLD
-
-
Master Real-Time Projects in DIgSILENT PowerFactory
17 Lessons-
StartIntroduction about real time projects 200MW solar power plant using Digsilent
-
StartInput preparation for 200MW solar power plant using Digsilent
-
StartSolar Plant system studies requirement
-
StartExcel Material
-
StartMV SLD
-
Start220kV Main SLD
-
StartIntroduction about DIgSILENT Software, Modelling of 230MW Solar Power Plant
-
StartCase Creation, Performing load flow analysis
-
StartInput received from client
-
StartInverter Data Sheet
-
StartDigsilent Simulation File
-
StartReal power control and Short circuit model of inverter
-
StartInverter Data sheet
-
Startsolar plant contribution to the fault
-
StartCEA and G99 code overview
-
StartStandard
-
StartReactive power capability study
-
-
RMS and EMT Study
24 Lessons-
StartIntroduction to RMS/EMT study
-
StartGrid code overview and software exploration in Dig silent
-
StartGrid code standard
-
StartResponse of Inverter dynamic model
-
StartFrequency response, voltage response and FRT
-
StartMaterials
-
StartIntroduction to transient stability
-
StartCrirical Clearing Time and Hands on
-
StartExcel
-
StartLoad addition, load rejection event creation with different study cases
-
StartHands on session
-
StartExcel
-
StartTransformer energization
-
StartTransformer energization with different case study
-
StartSimulation file
-
StartWord document
-
StartLine Energization and Line Reenergization
-
StartSurge Arrester sizing
-
StartSurge Arrester Buyers Guide Edition 6
-
StartExcel Sheet
-
StartQ&A session on Digsilent with Mr. Selvakumar
-
StartFrequency and Voltage Response
-
StartFault Ride Through
-
StartMaterials
-
-
Protection coordination
18 Lessons-
StartIntroduction to Protection in LV. Introduction to Fuse,MCB
-
StartDigsilent Exploration for relay functions
-
StartIntroduction about MCCB and ACB
-
StartLV motor protection and its manual calculation
-
StartIntroduction to Release
-
StartMotor protection using release
-
StartLV Release Coordination- DIgsilent
-
StartLV protection and coordination
-
StartMotor protection, Incomer Feeder protection and Transformer LV protection
-
StartOverview of MV protection
-
StartTransformer HV protection and its calculation
-
StartExcel calculation
-
StartDirectional protection for different system
-
StartIntroduction to Directional Protection
-
StartDirectional Classs
-
StartDifferential Protection
-
StartTransformer Differential Protection Relay
-
StartUnit Prot RET670
-
-
Harmonic Analysis
13 Lessons-
StartHarmonic Introduction
-
StartSimulation of Harmonic and filter sizing
-
StartImpact of source and System Impendace
-
StartVoltage harmonic conversion and impedance loci
-
StartTypes of Filter, Active and Passive Filter Overview
-
StartFilter designing and tuning
-
StartSC4600UP_harmonics_100th_preliminary
-
StartFilter
-
StartDP -02 HA-01
-
StartImpedance Loci, Norton equivalent of inverters
-
StartCase Study, Hands on
-
StartIdeal Vs Impedance Based Inverter Model
-
StartHarmonics Analysis hands on
-